• RE: (ADG736)Unused channel

    Hi Donadona999s,

    For the unused pins of the ADG736, it is recommended to tie it to a known state. In your case, tying it to ground.


    Best Regards,

    May

  • RE: ADG736 S overvoltage

    Hi,

    The ADG736 has overvoltage diodes to VDD and VSS. When an overvoltage occurs the diode becomes forward biased and current begins following from the input signal to the supplies. You would need to take into account how the current draw from your signal…

  • RE: ADG736BRM I2C Application

    Hello JDavis2014,

    There shouldn't be an issue using the ADG736 as a multiplexer for I2C. You need to ensure that the signals remain within the supply range of the multiplexer and from an I2C perspective, you should be conscious of the capacitance that…

  • RE: Differential signal Power divider

    Hi Tsingyang,

    I would recommend a multiplexer, a 2:1 MUX to be specific. You can find them in this link Selection Table for All Analog Switches and Multiplexers | Parametric Search | Analog Devices. For a quick suggestion, try looking at ADG824, ADG8…

  • RE: Accessing I2C on ADV7282-M evaluation board

    Hi Vincent,

    It is perfectly ok to connect an external I2C master to the ADV728x evaluation board using the SDA, SCL and GND pins.

    The on-board cypress microcontroller will only send I2C commands to the ADV728x if it is programmed to do so by the DVP_EVAL…

  • ADAU1761 jack detcetion

    Hello,

    I would like to detect which type of jack has been inserted and use analog switch ADG736 to connect signals properly. As you can see in picture below, in first stuation the tip is Headphone (L). When the mono mic is inserted tip is now microphone…

  • RE: AD719x Calibration: How is System Cal implemented?

    System calibration allows the converter to compensate for external system gain and offset errors as well as its own internal errors.

    Calibration is basically a conversion process on two specific input voltages (zero scale or offset calibration and full…

  • RE: What is system calibration and how is it implemented on the AD779x ?

    System calibration allows the converter to compensate for external system gain and offset errors, as well as its own internal errors. Calibration is basically a conversion process on two specific input voltages (zero-scale or offset calibration, and full…

  • RE: AD7195读取的寄存器不对

    如果软件出现问题,可以参考一下如下示例代码

    参考代码 | 亚德诺半导体

    此外附件中有常见问题解答,可以参考

  • RE: AD7194 Calibration data for 4 bipolar channels

    Hi ottelo,

    You can perform an offset calibration using the uC. So, for each load cell, read the conversion when there is no load on the load cell. This conversion is the offset. For further conversions, subtract the recorded offset value from the conversion…